    06/08/2018No Comments10 Mins Read

    Physical Topology Diagram

    • Visual Topology
    • Command List
    • Task 1: Reload and check that the Switch is set to factory defaults.
    • Task 2: Basic switch set-up.
    • Task 3: Configure basic VLAN and Trunk connections.
    • Task 4: Troubleshoot Trunk failure.

    Visual Topology

    Command List

    Command Description
    Configure Terminal Enters global configuration mode
    Copy run start Saves your dynamic running config to NVRAM
    Delete flash:vlan.dat Deletes a file
    Do command Allows for the execution of commands located in a different mode
    Enable Enters privileged EXEC mode from user EXEC mode
    End Terminates configuration mode
    Erase startup-config Erases the startup-configuration from NVRAM
    Exit Exits current configuration mode
    Hostname name Sets a system name and is displayed within the system prompt
    Interface type/slot/id Enters the interface configuration mode
    Interface Vlan 1 Enters the interface configuration (SVI) for Vlan 1 and allows you to set the management IP address for the switch
    IP address address & mask Set an IP address and also the network/subnet mask
    Line console 0 Enters line console configuration mode
    Logging synchronous Prevents unsolicited messages from interfering when typing in your commands
    Name vlan name Used in vlan configuration mode to assign a descriptive name
    Reload Restarts the device
    Show flash: Displays the contents of the flash memory
    Show startup-config Displays the startup-config saved in NVRam
    Show version Displays hardware and software information
    [no] Shutdown Disables or enables an interface
    Switchport access vlan id Assigns a switchport to a data vlan
    Switchport mode access Puts the switchport into access mode
    Switchport mode trunk Puts the switchport into trunk mode
    [no] Vlan id Deletes or creates a vlan and enters vlan configuration mode

    * The instructor will assign you with a student ID (student 1 to 16).*

    Please note that for this exercise students are expected to work in pairs.

    Refer to the Student Table 1 when allocating IP addresses and VLANs, failure to do so will result in IP address conflict messages and inconsistent lab results.

    Student Table 1.

    Student ID PC IP address & mask Switch SVI (VLAN 1) IP address VLAN assignments
    Pair 1 Student 1 10.2.2.101 /24 10.1.1.1 /24 2 & 3
    Pair 1 Student 2 10.2.2.102 /24 10.1.1.2 /24 2 & 3
    Pair 2 Student 3 10.2.2.103 /24 10.1.1.3 /24 2, 4 & 5
    Pair 2 Student 4 10.2.2.104 /24 10.1.1.4 /24 2, 4 & 5
    Pair 3 Student 5 10.2.2.105 /24 10.1.1.5 /24 2, 6 & 7
    Pair 3 Student 6 10.2.2.106 /24 10.1.1.6 /24 2, 6 & 7
    Pair 4 Student 7 10.2.2.107 /24 10.1.1.7 /24 2, 8 & 9
    Pair 4 Student 8 10.2.2.108 /24 10.1.1.8 /24 2, 8 & 9
    Pair 5 Student 9 10.2.2.109 /24 10.1.1.9 /24 2, 10 & 11
    Pair 5 Student 10 10.2.2.110 /24 10.1.1.10 /24 2, 10 & 11
    Pair 6 Student 11 10.2.2.111 /24 10.1.1.11 /24 2, 12 & 13
    Pair 6 Student 12 10.2.2.112 /24 10.1.1.12 /24 2, 12 & 13
    Pair 7 Student 13 10.2.2.113 /24 10.1.1.13 /24 2, 14 & 15
    Pair 7 Student 14 10.2.2.114 /24 10.1.1.14 /24 2, 14 & 15
    Pair 8 Student 15 10.2.2.115 /24 10.1.1.15 /24 2, 16 & 17
    Pair 8 Student 16 10.2.2.116 /24 10.1.1.16 /24 2, 16 & 17

    Task 1: Reload and check that the Switch is set to factory defaults.

    Step 1: Assign an IP address to your PC using the details listed in Student Table 1. The PC should be fitted with two network adapters check with the instructor if you are unsure which network adapter should be configured.

    Step 2: Access the Switch Console port using the method and information provided by the instructor.

    Enter into privilege mode and use the erase startup-config command to remove any previous saved configuration.

    (If you see any other prompt or are asked for a password contact the instructor).

    Step 3: Switches hold information about logical VLANs in a database stored in their flash memory and it is necessary to delete this database to reset the Switch back to factory defaults. PLEASE BE VERY CAREFUL WHEN USING THE DELETE COMMAND.

    From privilege mode type in the following command and follow the system messages (if you are unsure what to do, contact the instructor before answering any of the system messages).

    Switch#Delete flash:vlan.dat
    confirm the deletion

    Step 4: Reload the Switch.

    confirm the reload

    Please note the Switch may take a few minutes to reload.

    NB. ASK THE INSTRUCTOR TO RESET THE CORE_SW BACK TO FACTORY DEFAULTS!

    Task 2: Basic switch set-up

    Step 1: Change the hostname of the Switch to either SW1 or SW2

    Step 2: Assign your Switch a management IP address using the values identified in the table below.

    Device IP Address Mask SVI (logical interface)
    SW1 See Student Table 1 255.255.255.0 vlan 1
    SW2 See Student Table 1 255.255.255.0 vlan 1

    Remember to enable the SVI so the IP address is active.

    Task 3: Configure basic VLAN and Trunk connections.

    Step 1: Create the VLANs listed in Student Table 1 and label Vlan2 with your pair name.

    Example, student 7 needs to create VLANs 2, 8 and 9 and name Vlan 2, Pair4. Use the default names for the other Vlans created.

    Step 2: Disable interface fa0/1 and put it into an access state

    Hint….switchport mode ?

    Step 3: Re-assign interface fa0/1 and place it into Vlan 2

    Step 4: enable interface fa0/1

    Step 5: Disable all other interfaces except fa0/1 and Vlan 1

    Step 6: Configure interface fa0/3 and interface fa0/11 to support trunking without using a dynamic protocol trunking protocol.

    Hint…..switchport mode ?

    In the table below indicate which modes generate DTP messages.

    Switchport mode access
    Switchport mode trunk
    Switchport mode dynamic auto
    Switchport mode dynamic desirable

    What is the command for disabling DTP?

    Step 7: Enable interfaces fa0/3 and fa0/11 and disable DTP on all active interfaces.

    Task 4: Troubleshooting Trunk failures

    Step 1: Confirm with the instructor that the Core switch has been reset back to factory defaults?

    Step 2: Ask the instructor to configure all of the ports on the Core switch as ACCESS ports.

    When a switch has been reset to factory defaults and the ports have been set to access mode, what is the default allocated VLAN for the port?

    Step 3: From privilege mode execute the following commands.

    show interface fa0/3 switchport
    show interface fa0/11 switchport
    show interface fa0/1 switchport

    Below are examples of output generated on SW1 but results should be similar on SW2 also.

    Observe the Switchport status, Administrative mode, Operational mode.

    What do you think the Negotiation of Trunking: Off line indicates?

    Interface Fa0/1 is attached to your PC.

    Note that the Operational Mode is set to Static Access and the Access Mode VLAN is assigned to VLAN 2 with a name Pair1 (name will differ dependant on your pairings)

    Step 4: ASK the Instructor to configure and enable the SVI (VLAN1) interface on the Core switch with an IP address of 10.1.1.100 /24.

    Step 5: Ping 10.1.1.100 from you Switch

    Explain, why the PING worked? Remembering that you have configured the switchport which connects you to the Core Switch as a Trunk link, however the Core Switch is configured in Static Access mode.

    Step 6: From your PC ping 10.1.1.100.

    Why does it fail?

    Step 7: Save your running-config

    Lab Answer Keys:

    [sociallocker id=”4139″]

    Task 1: Reload and check that the Switch is set to factory defaults.

    Step 1: Assign an IP address to your PC using the details listed in the visual topology diagram. The PC should be fitted with two network adapters, check with the instructor if you are unsure which network adapter should be configured.

    Step 2: Access the Switch Console port using the method and information provided by the instructor.

    Enter into privilege mode and use the erase startup-config command to remove any previous saved configuration.

    Switch>enable
    Switch#erase-config

    Confirm action and do not save if prompted.

    Step 3: Deleting the vlan database

    Switch#Delete flash:vlan.dat
    confirm the deletion

    Step 4: Reload the Switch.

    Switch#reload
    confirm the reload

    Task 2: Basic switch set-up

    Step 1: Change the hostname of the Switch to either SW1 or SW2

    Switch(config)#hostname SW1

    or

    Switch(config)#hostname SW2

    Step 2: Assign your Switch a management IP address using the values identified in the table below.

    Device IP Address Mask SVI (logical interface)
    SW1 See Student Table 1 255.255.255.0 vlan 1
    SW2 See Student Table 1 255.255.255.0 vlan 1

    Remember to enable the SVI so the IP address is active.

    SW1(config)#interface vlan 1
    SW1(config-if)#ip address 10.1.1.x 255.255.255.0
    SW1(config-if)#no shut

    or

    SW2(config)#interface vlan 1
    SW2(config-if)#ip address 10.1.1.x 255.255.255.0
    SW2(config-if)#no shut

    Task 3: Configure basic VLAN and Trunk connections.

    Step 1: Create Vlan 2 and label it with a name of PAIRx

    SW(config)#vlan 2
    SW(config-vlan)#name PAIRx

    Step 2: Disable interface fa0/1 and put it into an access state

    SW(config)#int fa0/1
    SW(config-if)#shut
    SW(config-if)#switchport mode access

    Step 3: Re-assign interface fa0/1 and place it into Vlan 2

    SW(config-if)#switchport access vlan 2

    Step 4: enable interface fa0/1

    SW(config-if)#no shut

    Step 5: Disable all other interfaces except fa0/1 and Vlan 1

    SW(config)#int range fa0/2 - 24
    SW(config-if-range)#shut

    Step 6: Configure interface fa0/3 and interface fa0/11 to support trunking without using a dynamic protocol trunking protocol.

    SW(config)#int fa0/3
    SW(config-if)#switchport mode trunk

    In the table below indicate which modes generate DTP messages.

    Active will send DTP messages, Passive will only receive.

    Switchport mode access Active operational state access only
    Switchport mode trunk Active operational state trunk only
    Switchport mode dynamic auto Passive operational state either trunk or access
    Switchport mode dynamic desirable Active operational state either trunk or access

    What is the command for disabling DTP?

    SW(config-if)#switchport nonegotiate

    Step 7: Enable interfaces fa0/3 and fa0/11 and disable DTP on all active interfaces.

    SW(config)#int range fa0/1, fa0/3, fa0/11
    SW(config-if-range)#switchport nonegotiate
    SW(config-if-range)#no shut

    Task 4: Troubleshooting Trunk failures

    Step 2: Ask the instructor to configure all of the ports on the Core switch as ACCESS ports.
    When a switch has been reset to factory defaults and the ports have been set to access mode, what is the default allocated VLAN for the port?

    VLAN 1

    Step 3: From privilege mode execute the following commands.

    show interface fa0/3 switchport
    show interface fa0/11 switchport
    show interface fa0/1 switchport

    Below are examples of output generated on SW1 but results should be similar on SW2 also.

    Observe the Switchport status, Administrative mode, Operational mode.

    What do you think the Negotiation of Trunking: Off line indicates?

    DTP is turned off

    Step 4: ASK the Instructor to configure and enable the SVI (VLAN1) interface on the Core switch with an IP address of 10.1.1.100 /24.

    Step 5: Ping 10.1.1.100 from you Switch

    Explain, why the PING worked? Remembering that you have configured the switchport which connects you to the Core Switch as a Trunk link, however the Core Switch is configured in Static Access mode.

    The switches will still communicate with each other if their operational states are different. Our configuration shows the Core Switch set to access mode vlan 1 and your switch set to Trunk with a native vlan of 1, and because the PING originates from vlan 1 your switch will send the PING frame down the trunk link untagged which will then be received at the core switch.

    Step 6: From your PC ping 10.1.1.100.

    Why does it fail?

    The PC is connected to switchport fa0/1 which was reassigned to vlan 2 earlier in the exercise, ports placed in vlan 2 can only communicate to other ports in vlan 2 unless layer 3 routing has been configured.

    Step 7: Save your running-config

    SW#copy run start

    [/sociallocker]

    Share. Facebook Twitter Pinterest LinkedIn Tumblr Email
    Previous ArticleLab 5-2: Configure IPv6 Routing
    Next Article Lab 1-2: Optimizing STP

    Related Posts

    ICND2 Labs

    Lab 5-2: Establishing a Frame Relay Connection

    18/08/2018
    ICND2 Labs

    Lab 5-1: Setting up a Serial Connection

    17/08/2018
    ICND2 Labs

    Lab 4-2: Implementing OSPF for IPv6

    16/08/2018
    Subscribe
    Notify of
    guest

    guest

    This site uses Akismet to reduce spam. Learn how your comment data is processed.

    0 Comments
    Oldest
    Newest Most Voted
    Inline Feedbacks
    View all comments
    Tags
    apache centos Centos 6 cuda Desktop Environment dual boot environment featured gnome GUI hostname hosts intel kernel kill lamp server lemp server life MariaDB netflix nginx nvidia password php-fpm phpmyadmin pids processes s.m.a.r.t Security session solid state drive ssd ssh ssh server tag 1 tag 2 Ubuntu upgrade varnish VirtualBox VNC Server web server window manager wordpress xfce
    Facebook X (Twitter) Instagram Pinterest

    Type above and press Enter to search. Press Esc to cancel.

    wpDiscuz